null
Menu Toggle

Menu

Search Box
Search Box

3ft LED T8 DirectDrive Tube - 12 Watt - 1200 Lumens - Direct Wire - Keystone

3ft LED T8 DirectDrive Tube - 12 Watt - 1200 Lumens - Direct Wire - Keystone
SKU: LEDLGHT1000036702
MPN: KT-LED12T8-36GC-8xx-D
$12.74
    • Brand: Keystone
    • Replaces: 3ft Fluorescent Tube
    • Watts: 12
    • Lumens: 1200
    • 100 lm/W
    • Available in 3000K and 4000K
    • Base: G13 Medium Bi-Pin
    • 50,000 Life Hours / 5 Year Warranty
Color Temperature Guide
Availability: In Stock
$12.74

  • Details

    Keystone makes upgrading fluorescent lights to LED easy with their UL Type B DirectDrive tubes. These innovative LED tubes eliminate the need for an external driver or ballast. By using a ballast bypass design, there’s one less possible point of failure, making the fixture more reliable. Ballast bypass LED tubes will also save time finding a compatible ballast.

    Upgrading fluorescent lights to LED will save time and money in maintenance costs. When a fluorescent light is frequently turned on and off the lifespan is reduced, whereas LED tubes aren’t affected nearly as much. Upgrading fluorescent lights to LED will also improve the quality and energy efficiency of a lighting system. UL Type B LED tubes prevent energy being wasted as it passes through a ballast.

    This LED tube is also DLC V5.1 listed meaning it is highly energy efficient and may qualify for utility rebates in certain areas. Check out our Rebate Assistant tool to find if this product qualifies for you!

    Direct Drive LED Tube Benefits

    • Improves reliability and efficiency of fixture with ballast bypass design
    • Saves time, no need to find a compatible ballast
    • Reduces maintenance costs compared to fluorescent equivalents
    • Extends lifespan and conserves energy compared to fluorescent equivalents

    Product Features

    • Type B - Ballast Bypass LED Linear Tube
    • Integral Keystone driver
    • Instant startup
    • Operating temperature: -20°C/-4°F to 45°C/113°F
    • Environmentally friendly: no mercury used like in conventional fluorescent lamps
    • Shatterproof Coated Glass with frosted lens eliminates pixelation
    • Integral driver (isolated), eliminates the need for an external driver or ballast
    • Single ended power
      • Use only non-shunted lampholders.
    • Suitable for use in dry and damp locations
    • 110+ lumens per watt
    • UL Classified, ETL Listed, RoHS Compliant, DLC listed
    • Available in 3000K, 3500K, 4000K, 5000K, and 6000K Color Temperatures

    Product Dimensions: 35.19" L x 1.1" D

    Can you put led tube lights in a fluorescent fixture? Can I replace my fluorescent T8 linear bulbs with LEDs?

    Yes! LED Tubes can be installed into a fluorescent fixture. When tubes are Type A + B. Type A or Type B, it is easy to replace those flickering fluorescents. A brief explanation of Type A and B LED linear tubes is below.

    Type A LED Linear Tubes are often called "plug and play" tubes. This is because they can simply be installed into the existing fixture.

    Type B LED Linear Tubes are often referred to as "ballast bypass." They work with all fluorescent fixtures including ballast-free fixtures. Type B linear tubes power goes directly to the lamp sockets and no longer through the ballast.

    Type A + B can be used with or without a ballast. It is ultimately the buyer's preference what they want to do. Type A installation uses the LED Tube + Ballast power for more energy consumption compared to Type B installation only uses the raw tube power and is more energy-efficient.

    What does ballast bypass mean? How does ballast bypass work?

    Ballast bypass means when installing the LED linear tube, the fixture's ballast will need to be removed first. The power will then go directly to the lamp sockets and no longer through the ballast. The benefits of ballast bypass LED replacement tubes include lights not being shut down by a ballast failure, no more ballast replacements, and savings on the energy bill because energy is no longer drawing from the ballast.

    Emergency Drivers: Constant-power emergency drivers with 90-minute run time are available to add on to your LED high bays to increase fire safety and comply with local fire safety codes. Check out our selection of LED emergency drivers.

    Want to learn more about getting our products at wholesale discounts? Buy LightUp LED Products in Bulk by completing the form on our wholesale page.

    Check out all that LightUp has to offer on weekly specials, new products, categories and more on our home page!

  • Warranty Information
  • Additional Information
    Case Qty 25
    Color 3000K Soft White
    Color 4000K Bright White
    Color 5000K Cool White
    Color 6000K Pure White
    Country Of Origin China
    Season Everyday
    Warranty 5 Year
    Base Type G13
    Compatibility Type B - Direct Wire / Ballast Bypass
    CRI 80
    Features Instant On
    Features Shatter Resistant
    Features Suitable for Damp Locations
    Features Warranty
    Length 3 ft.
    Life Hours 50,000 Hours
    Light Source LED
    Lumens per Watt 100 lm/W
    Lumens Range 800 - 1,500 Lumens
    Recommended Uses rohs_compliant.png
    Recommended Uses damp_location.png
    Recommended Uses dlc_listed.png
    Recommended Uses ul_listed.png
    Shape T8
    Voltage AC120-277V
    Color 3500K Bright Warm
    Beam Angle 240 Degrees
    Operating Temp - High 45C / 113F
    Operating Temp - Low -20C / -4F
    Operation Single Ended Power
    Product Type LED T8 Tubes
    Lumens 1300-1550
    Ratings and Certifications DLC Listed
    Ratings and Certifications ETL Listed
    Ratings and Certifications RoHS Compliant
    Ratings and Certifications UL Listed
    Dimensions Length: 36in | Width: 1.25in | Height: 1.25in
    Wattage 12W
    Clearance Clearance
    Return Policy Not Returnable
    Right Overlay Image Direct Wire.png
    Brand Keystone

Keystone makes upgrading fluorescent lights to LED easy with their UL Type B DirectDrive tubes. These innovative LED tubes eliminate the need for an external driver or ballast. By using a ballast bypass design, there’s one less possible point of failure, making the fixture more reliable. Ballast bypass LED tubes will also save time finding a compatible ballast.

Upgrading fluorescent lights to LED will save time and money in maintenance costs. When a fluorescent light is frequently turned on and off the lifespan is reduced, whereas LED tubes aren’t affected nearly as much. Upgrading fluorescent lights to LED will also improve the quality and energy efficiency of a lighting system. UL Type B LED tubes prevent energy being wasted as it passes through a ballast.

This LED tube is also DLC V5.1 listed meaning it is highly energy efficient and may qualify for utility rebates in certain areas. Check out our Rebate Assistant tool to find if this product qualifies for you!

Direct Drive LED Tube Benefits

  • Improves reliability and efficiency of fixture with ballast bypass design
  • Saves time, no need to find a compatible ballast
  • Reduces maintenance costs compared to fluorescent equivalents
  • Extends lifespan and conserves energy compared to fluorescent equivalents

Product Features

  • Type B - Ballast Bypass LED Linear Tube
  • Integral Keystone driver
  • Instant startup
  • Operating temperature: -20°C/-4°F to 45°C/113°F
  • Environmentally friendly: no mercury used like in conventional fluorescent lamps
  • Shatterproof Coated Glass with frosted lens eliminates pixelation
  • Integral driver (isolated), eliminates the need for an external driver or ballast
  • Single ended power
    • Use only non-shunted lampholders.
  • Suitable for use in dry and damp locations
  • 110+ lumens per watt
  • UL Classified, ETL Listed, RoHS Compliant, DLC listed
  • Available in 3000K, 3500K, 4000K, 5000K, and 6000K Color Temperatures

Product Dimensions: 35.19" L x 1.1" D

Can you put led tube lights in a fluorescent fixture? Can I replace my fluorescent T8 linear bulbs with LEDs?

Yes! LED Tubes can be installed into a fluorescent fixture. When tubes are Type A + B. Type A or Type B, it is easy to replace those flickering fluorescents. A brief explanation of Type A and B LED linear tubes is below.

Type A LED Linear Tubes are often called "plug and play" tubes. This is because they can simply be installed into the existing fixture.

Type B LED Linear Tubes are often referred to as "ballast bypass." They work with all fluorescent fixtures including ballast-free fixtures. Type B linear tubes power goes directly to the lamp sockets and no longer through the ballast.

Type A + B can be used with or without a ballast. It is ultimately the buyer's preference what they want to do. Type A installation uses the LED Tube + Ballast power for more energy consumption compared to Type B installation only uses the raw tube power and is more energy-efficient.

What does ballast bypass mean? How does ballast bypass work?

Ballast bypass means when installing the LED linear tube, the fixture's ballast will need to be removed first. The power will then go directly to the lamp sockets and no longer through the ballast. The benefits of ballast bypass LED replacement tubes include lights not being shut down by a ballast failure, no more ballast replacements, and savings on the energy bill because energy is no longer drawing from the ballast.

Emergency Drivers: Constant-power emergency drivers with 90-minute run time are available to add on to your LED high bays to increase fire safety and comply with local fire safety codes. Check out our selection of LED emergency drivers.

Want to learn more about getting our products at wholesale discounts? Buy LightUp LED Products in Bulk by completing the form on our wholesale page.

Check out all that LightUp has to offer on weekly specials, new products, categories and more on our home page!

Case Qty 25
Color 3000K Soft White
Color 4000K Bright White
Color 5000K Cool White
Color 6000K Pure White
Country Of Origin China
Season Everyday
Warranty 5 Year
Base Type G13
Compatibility Type B - Direct Wire / Ballast Bypass
CRI 80
Features Instant On
Features Shatter Resistant
Features Suitable for Damp Locations
Features Warranty
Length 3 ft.
Life Hours 50,000 Hours
Light Source LED
Lumens per Watt 100 lm/W
Lumens Range 800 - 1,500 Lumens
Recommended Uses rohs_compliant.png
Recommended Uses damp_location.png
Recommended Uses dlc_listed.png
Recommended Uses ul_listed.png
Shape T8
Voltage AC120-277V
Color 3500K Bright Warm
Beam Angle 240 Degrees
Operating Temp - High 45C / 113F
Operating Temp - Low -20C / -4F
Operation Single Ended Power
Product Type LED T8 Tubes
Lumens 1300-1550
Ratings and Certifications DLC Listed
Ratings and Certifications ETL Listed
Ratings and Certifications RoHS Compliant
Ratings and Certifications UL Listed
Dimensions Length: 36in | Width: 1.25in | Height: 1.25in
Wattage 12W
Clearance Clearance
Return Policy Not Returnable
Right Overlay Image Direct Wire.png
Brand Keystone