MSA ALTAIR 5X Multigas Detector (LEL, O2, CO, H2S) (UL) - 10116924

MSA ALTAIR 5X Multigas Detector (LEL, O2, CO, H2S) (UL) - 10116924
SKU: DSG_MSA_10116924
MPN: 10116924
$2,751.49
$2751.49 per unit
    • Standard 4 sensors
    • Detects combustible gases in LEL and/or volume percentage range
    • Ability to survive 10-ft. (3m) drop; IP65-certified
    • Field-proven integral pump
    • High performance XCell Sensors last longer
    • Wireless bluetooth included standard.
Availability: In Stock: Ships in 7 to 10 business days
$2,751.49

  • Details

    The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell Sensor Technology,  the ALTAIR 5X Gas Detector delivers  faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

    • Detects combustible gases in LEL and/or volume percentage range, oxygen, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur  dioxide, ammonia, chlorine, VOCs,  and many others depending upon sensor configuration.
    • Rugged overmolded polycarbonate housing provides unsurpassed durability, including ability to survive 10-ft. (3m) drop
    • IP65-certified.
    • Field-proven integral pump provides consistent gas flow, eliminating concerns of externally-attached components.
    • High performance XCell Sensors last longer:
    • Typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors.
    • Typical life greater than 3 years for NH3 and Cl2 sensors.
    • Most sensor response and clear times
    • Less calibration gas used:
    • Requires about half of test gas typically used for calibration and bump tests.
    • Rapid bump test gives results in less than 10 seconds for most common sensor configurations.
    • Span calibration time of 60 seconds for most common sensor configurations.
    • MotionAlert feature option tells others that user has become immobile.
    • InstantAlert feature provides manual alarm to alert others as to a potentially hazardous situation.
    • PID option allows for accurate, reliable VOC response with programmable reference factors.
    • Large buttons and bright display provide easy operation, even when users wear gloves.
    • Exclusive end-of-sensor warning cautions users when unit's sensor nears end-of-life.
    • Versatile MSA Link Software allows users to transmit data to a computer.
    • Compatible with GALAXY GX2 Test System and MSA Link Pro Software for fleet management.
    • Wireless bluetooth included standard.
  • Additional Information
    Clearance Non-Clearance
    Color Gray
    Color Name Charcoal
    Country Of Origin United States
    Product Type Gas Detection
    Product Type Gas Detectors
    Season Everyday
    Type Multi-Gas
    HR-mail-only true
    Left Overlay Image Made in the USA.png
    Brand MSA

The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell Sensor Technology,  the ALTAIR 5X Gas Detector delivers  faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

  • Detects combustible gases in LEL and/or volume percentage range, oxygen, carbon monoxide, carbon dioxide, hydrogen sulfide, sulfur  dioxide, ammonia, chlorine, VOCs,  and many others depending upon sensor configuration.
  • Rugged overmolded polycarbonate housing provides unsurpassed durability, including ability to survive 10-ft. (3m) drop
  • IP65-certified.
  • Field-proven integral pump provides consistent gas flow, eliminating concerns of externally-attached components.
  • High performance XCell Sensors last longer:
  • Typical life greater than 4 years for combustible, O2, CO/H2S, SO2, CO/NO2 and CO (high concentration) sensors.
  • Typical life greater than 3 years for NH3 and Cl2 sensors.
  • Most sensor response and clear times
  • Less calibration gas used:
  • Requires about half of test gas typically used for calibration and bump tests.
  • Rapid bump test gives results in less than 10 seconds for most common sensor configurations.
  • Span calibration time of 60 seconds for most common sensor configurations.
  • MotionAlert feature option tells others that user has become immobile.
  • InstantAlert feature provides manual alarm to alert others as to a potentially hazardous situation.
  • PID option allows for accurate, reliable VOC response with programmable reference factors.
  • Large buttons and bright display provide easy operation, even when users wear gloves.
  • Exclusive end-of-sensor warning cautions users when unit's sensor nears end-of-life.
  • Versatile MSA Link Software allows users to transmit data to a computer.
  • Compatible with GALAXY GX2 Test System and MSA Link Pro Software for fleet management.
  • Wireless bluetooth included standard.
Clearance Non-Clearance
Color Gray
Color Name Charcoal
Country Of Origin United States
Product Type Gas Detection
Product Type Gas Detectors
Season Everyday
Type Multi-Gas
HR-mail-only true
Left Overlay Image Made in the USA.png
Brand MSA